Second Acceleration and Deceleration Functions
The SJ100 inverter features two-stage acceleration and deceleration ramps. This gives
flexibility in the profile shape. You can specify the frequency transition point, the point
at which the standard acceleration (F_02) or deceleration (F_03) changes to the second
acceleration (A_92) or deceleration (A_93). These profile options are also available for
the second motor settings. Select a transition frequency method via A_94 as depicted
below. Be careful not to confuse the second acceleration/deceleration settings with
settings for the second motor!
Accel 1
Accel 2
2CH
input
Frequency
transition point
A95
A_94 = 00 A_94 = 01
Output
frequency
Output
frequency
t
t
Accel 1
Accel 2
t
Transition via 2CH input Transition via freq. level
00
1
0
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
Units
A_92 Acceleration (2) time
setting
Duration of 2nd segment of
acceleration, range is:
0.1 to 3000 sec.
15.0 15.0 15.0 sec.
ACC 2 0015.0s
A292 Acceleration (2) time
setting, (2nd motor)
Duration of 2nd segment of
acceleration, 2nd motor,
range is: 0.1 to 3000 sec.
15.0 15.0 15.0 sec.
2ACC2 0015.0s
A_93 Deceleration (2) time
setting
Duration of 2nd segment of
deceleration, range is:
0.1 to 3000 sec.
15.0 15.0 15.0 sec.
DEC 2 0015.0s
A293 Deceleration (2) time
setting, (2nd motor)
Duration of 2nd segment of
deceleration, 2nd motor,
range is: 0.1 to 3000 sec.
15.0 15.0 15.0 sec.
2DEC2 0015.0s
A_94 Select method to switch
to Acc2/Dec2 profile
Two options for switching
from 1st to 2nd accel/decel:
00... 2CH input from terminal
01... transition frequency
00 00 00
ACC CHG TM
A294 Select method to switch
to Acc2/Dec2 profile,
2nd motor
Two options for switching
from 1st to 2nd accel/decel:
00... 2CH input from terminal
01... transition frequency
(2nd motor)
00 00 00
2ACCCHG TM