Hitachi SJ100 Power Supply User Manual


 
SJ100 Inverter
Troubleshooting
and Maintenance
6–7
Trip History and Inverter Status
We recommend that you first find the cause of the fault before clearing it. When a fault
occurs, the inverter stores important performance data at the moment of the fault. To
access the data, use the monitor functions (D_xx) and select D_08 for details about the
present fault (E
n
), or the error code for the past two trip events (E
n-1
and E
n-2
) using the
D_09 Trip History function.
The following Monitor Menu map shows how to access the error codes. When fault(s)
exist, you can review their details by first selecting the proper function: D_08 displays
current trip data, and D_09 displays trip history.
2
1
Error Code
Previous
error #1
FUNC.
FUNC.
FUNC.
FUNC.
FUNC.
FUNC.
Output frequency
at trip point
Motor current
at trip point
DC bus voltage
at trip point
No error
Ye s
No
FUNC.
Ye s
No
Ye s
No
Previous
error #2
FUNC.
No
history
No
history
FUNC.
FUNC.
FUNC.
2
1
2
2
d 08
E09
d 01
d 09
10.0
0.25
189.8
___
E03 ___
___
E05
Monitor Menu
Current Trip
Conditions
Trip History
Error
(n-1)
exists?
Error
exists?
Error
(n-2)
exists?