SJ200 Inverter
Appendix B
B–39
Note 1: Assume that the inverter current rating is 10000 (for C041).
The following table lists the holding registers for the “H” Group Motor Constants.
C146 Terminal [12] ON delay R/W Range is 0.0 to 100.0 sec. 00F4h 0 to 1000 0.1 sec
C147 Terminal [12] OFF
delay
R/W Range is 0.0 to 100.0 sec. 00F5h 0 to 1000 0.1 sec
C148 Output relay ON delay R/W Range is 0.0 to 100.0 sec. 00F6h 0 to 1000 0.1 sec
C149 Output relay OFF delay R/W Range is 0.0 to 100.0 sec. 00F7h 0 to 1000 0.1 sec
“C” Group Intelligent Terminal Functions
Func.
Code
Name R/W Description
Network Data
Reg. Range Res.
“H” Group Motor Constants
Func.
Code
Name R/W Description
Network Data
Reg. Range Res.
H003 Motor capacity R/W Thirteen selections:
0.....0.20 kW
1.....0.37 kW
2.....0.40 kW
3.....0.55 kW
4.....0.75 kW
5.....1.10 kW
6.....1.50 kW
7.....2.2 kW
8.....3.0 kW
9.....3.7 kW
10...4.0 kW
11...5.5 kW
12...7.5 kW
00D9h 0 to 12 —
H203 Motor capacity, 2nd
setting
R/W 00DAh 0 to 12 —
H004 Motor poles setting R/W Four selections:
2 / 4 / 6 / 8
00DBh 2, 4, 6,
8
1 pole
H204 Motor poles setting, 2nd
motor
R/W 00DCh 2, 4, 6,
8
1 pole
H006 Motor stabilization
constant
R/W Motor constant (factory set),
range is 0 to 255
00DDh 0 to 255 1
H206 Motor stabilization
constant, 2nd motor
R/W 00DEh 0 to 255 1
H007 Motor voltage select R/W Two selections, option codes:
00...200V
01...400V
00DFh 0, 1 —
H207 Motor voltage select,
2nd motor
R/W 00E0h 0, 1 —