Accel/Decel
Standard acceleration and deceleration is
linear. The inverter CPU can also calculate
an S-curve acceleration or deceleration
curve as shown. This profile is useful for
favoring the load characteristics in particu-
lar applications.
Curve settings for acceleration and decel-
eration are independently selected. To
enable the S-curve, use function A097
(acceleration) and A098 (deceleration).
Acceleration period
S-curve
Linear
Accel. curve selection
Target
freq.
Output
frequency
t
0
A097
=
00
A097
=
01
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FEF
(EU)
–FU
(USA)
Units
A097 Acceleration curve
selection
Set the characteristic curve of
Acc1 and Acc2, two options:
00...linear
01...S-curve
00 00
ACC LINE L
A098 Deceleration curve
selection
Set the characteristic curve of
Acc1 and Acc2, two options:
00...linear
01...S-curve
00 00
DEC LINE L