Hitachi SJ200 Series Power Supply User Manual


 
SJ200 Inverter
Configuring
Drive Parameters
3–3
Using Keypad Devices
The SJ200 Series inverter front keypad contains all the elements for both monitoring and
programming parameters. The keypad layout is pictured below. All other programming
devices for the inverter have a similar key arrangement and function.
Key and Indicator Legend
Run/Stop LED - ON when the inverter output is ON and the motor is developing
torque (Run Mode), and OFF when the inverter output is OFF (Stop Mode).
Program/Monitor LED - This LED is ON when the inverter is ready for parameter
editing (Program Mode). It is OFF when the parameter display is monitoring data
(Monitor Mode).
Run Key Enable LED - is ON when the inverter is ready to respond to the Run key,
OFF when the Run key is disabled.
Run Key - Press this key to run the motor (the Run Enable LED must be ON first).
Parameter F004, Keypad Run Key Routing, determines whether the Run key generates
a Run FWD or Run REV command.
Stop/Reset Key - Press this key to stop the motor when it is running (uses the
programmed deceleration rate). This key will also reset an alarm that has tripped.
Potentiometer - Allows an operator to directly set the motor speed when the potenti-
ometer is enabled for output frequency control.
Potentiometer Enable LED - ON when the potentiometer is enabled for value entry.
Parameter Display - A 4-digit, 7-segment display for parameters and function codes.
Display Units, Hertz/Amperes - One of these LEDs will be ON to indicate the units
associated with the parameter display.
Power LED - This LED is ON when the power input to the inverter is ON.
Alarm LED - ON when an inverter trip is active (alarm relay contacts will be closed).
Function Key - This key is used to navigate through the lists of parameters and
functions for setting and monitoring parameter values.
Up/Down ( , ) Keys - Use these keys alternately to move up or down the lists of
parameter and functions shown in the display, and increment/decrement values.
Store ( ) Key - When the unit is in Program Mode and you have edited a parameter
value, press the Store key to write the new value to the EEPROM.
Function key
Up/Down keys
Store key
POWER
RUN
PRG
RUN
STOP
RESET
HITACHI
FUNC
STR
1
2
Parameter Display
Run/Stop LED
Program/Monitor LED
Run Key Enable LED
Run Key
Stop/Reset Key
Power LED
Display Units (Hertz / Amperes) LEDs
Potentiometer Enable LED
Potentiometer
50.0
Hz
A
HITACHI
ALARM
Alarm LED
1
2
STR