Hitachi SJ200 Series Power Supply User Manual


 
SJ200 Inverter
Appendix C
C–7
Fine Tuning Functions
“B” Group Parameters Default Setting
User
Setting
Func.
Code
Name
-FEF
(EU)
-FU
(USA)
B001 Selection of automatic restart
mode
00 00
B002 Allowable under-voltage power
failure time
1.0 1.0
B003 Retry wait time before motor
restart
1.0 1.0
B004 Instantaneous power failure /
under-voltage trip alarm enable
00 00
B005 Number of restarts on power
failure / under-voltage trip events
00 00
B012 Level of electronic thermal
setting
Rated
current for
each
inverter
Rated
current for
each
inverter
B212 Level of electronic thermal
setting, 2nd motor
Rated
current for
each
inverter
Rated
current for
each
inverter
B013 Electronic thermal characteristic 01 01
B213 Electronic thermal characteristic,
2nd motor
01 01
B021 Overload restriction operation
mode
01 01
B022 Overload restriction setting Rated
current x
1.5
Rated
current x
1.5
B023 Deceleration rate at overload
restriction
1.0 30.0
B031 Software lock mode selection 01 01
B080 [AM] analog signal gain 100. 100.
B082 Start frequency adjustment 0.5 0.5
B083 Carrier frequency setting 5.0 5.0
B084 Initialization mode (parameters
or trip history)
00 00
B085 Country code for initialization 01 02
B086 Frequency scaling conversion
factor
1.0 1.0