IBM 440 Server User Manual


 
Chapter 4. Installation 125
4. Start NetWare server and go to the NetWare Console.
Type LOAD C:\IBMXSBD.NLM
Wait until a message indicates that IBMXSBD is ready for operation.
5. Restart the server.
6. To verify the installation, load the Novell Configuration Manager,
NCMCON.NLM. This will show the available hot-plug PCI slots, their current
status, and any adapters that are currently in the hot-plug PCI slots, as shown
in Figure 4-12.
Figure 4-12 Verifies that PCI hot-plug installation was successful
Highlighting a slot and pressing Enter shows the details for that slot.
Figure 4-13 on page 126 shows the details for slot 12.
If NCMCON.NLM does not show any slots with Ye s in the Hot Plug field, the
IBMXSBD.NLM module is not loaded. To fix the problem, exit NCMCON, load
IBMXSBD at the system console, and reload NCMCON.
Tip: Add the IBMXSBD to AUTOEXEC.NCF to run it each time NetWare
starts.