9. When reconstruction is finished on the new drive, repeat step 5 on page 81
through step 8 on page 81 for each additional drive that you want to install.
10. Use the DS3000 Storage Manager software to configure the additional space
on the new drives.
Replacing a power supply
(L003)
1
2
or
!
1
2
The power-supply unit is a component that includes a 515-watt power supply and
two fans. The power-supply units provide power and cooling for the DS3200. The
power-supply units circulate air from the front to the rear of the storage subsystem.
The power-supply units are customer replaceable units (CRUs) and do not require
preventive maintenance. Use only the supported power-supply units for the specific
storage subsystem.
Each power supply has a built-in sensor that detects the following conditions:
v Over-voltage
v Over-current
v Overheated power supply
If any of these conditions occurs, one or both power supplies will shut down. If the
power remains off (does not automatically restart), make sure that the environment
82 System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide