IBM DS3200 Storage Subsystem Tablet Accessory User Manual


 
15. Verify the state of the LEDs on the newly inserted controller. See “Controller
LEDs” on page 53. You can also use the DS3000 Storage Manager
Subsystem Management window to identify any new faults. Do any storage
subsystems have a fault (Needs Attention) status?
v Yes: Click Recovery Guru in the Subsystem Management window toolbar,
and complete the recovery procedure. If the problem remains, contact your
IBM technical-support representative.
v No: Go to step 16.
16. Use the DS3000 Storage Manager software to print a new storage subsystem
profile.
Working with hot-swap hard disk drives
This section explains how you can increase the storage subsystem capacity by
adding more hard disk drives or by replacing existing drives with ones that have a
larger capacity.
Before you begin, complete the following tasks:
v Read the safety information that begins on page xi and “Handling static-sensitive
devices” on page 19.
v Make sure that the current system configuration is working correctly.
v Back up all important data before you make changes to data storage devices.
Before you install or remove drives, review the following information:
v Filler panels: A storage subsystem without a full set of drives (12) contains filler
panels in the unused drive bays. Before you install new drives, you must remove
these filler panels. Save the filler panels for future use. For proper cooling and
EMC protection, each of the 12 bays must always contain either a filler panel or
a hot-swap hard disk drive.
v Drives:
The DS3200 supports 3 Gbps SAS or SATA hard disk drives.
For optimum performance, never insert a drive into the storage subsystem
without first confirming the drive firmware level. Contact your IBM
technical-support representative for information about supported drive
firmware levels.
Use of unsupported drives can cause the storage subsystem to fail.
After you remove a drive, wait 70 seconds before you replace or reseat the
drive to allow the drive to spin down. Failure to do so might cause
unpredictable results.
72 System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide