SRP_USER_CODE
The abend occurred while running user application
code.
SRP_PPT_ENTRY
The abend occurred while running
SRP_ERROR_PPT_NAME. If this flag is not set,
the abend occurred while running
SRP_ERROR_STACK_NAME.
SRP_VALID_OFFSET
A meaningful offset could be determined.
SRP_VALID_REASON
MVS has supplied a reason code for the abend.
SRP_NOT_CICS_RB
CICS RB was not in control at the time of the
abend (that is, the abend occurred in a system
service invoked by CICS).
SRP_CICS_ERROR_REASON
4-character field containing the MVS abend reason code. It
contains a value only if flag SRP_VALID_REASON is set.
SRP_CICS_ERROR_DATA
An area describing the last thing that CICS did, prior to the
abend. It contains the following:
SRP_CICS_EC_PSW
8-character field containing the extended control
(EC) mode program status word (PSW)
SRP_CICS_EC_INT
8-character field containing the interrupt code and
ILC
SRP_CICS_REGST
64-character field containing the contents of the
general-purpose (GP) registers
SRP_CICS_EXEC_KEY
1 byte containing the PSW key, in the form X'0n'.
SRP_SYSTEM_ERROR_DATA
An area describing the last thing “the system” did, prior to
the abend. It contains the following:
SRP_SYSTEM_EC_PSW
8-character field containing the EC mode PSW
SRP_SYSTEM_EC_INT
8-character field containing the interrupt code and
ILC
SRP_SYSTEM_REGST
64-character field containing the contents of the GP
registers
SRP_SYSTEM_EXEC_KEY
1 byte containing the PSW key, in the form X'0n'.
system recovery program exit