IBM SC33-1683-02 Server User Manual


 
Important
The E1/T2 and E2/T5 cycles can be used repeatedly. This may occur, for
example, if the EDF user changes the screen a number of times.
Adapter administration
Careful use of task-related user exits can allow your application programmers to be
unaffected by the invocation of non-CICS resource managers from CICS application
programs. Enabling and disabling task-related user exit programs for an installation
should be the responsibility of one or more supervisory or master terminal
operators. This section lists what you must do before you can use the adapter, and
describes the commands used by the supervisor to administer task-related user exit
programs.
For programming information about the use of commands in CICS application
programs, see the
CICS Application Programming Reference
manual.
What you must do before using the adapter
1. A task-related user exit program must be defined to the system using the CEDA
INSTALL PROGRAM command.
2. To enable the task-related user exit program and to define its working storage
needs, you must use the EXEC CICS ENABLE command. A task-related user
exit program must be both enabled and started before it is available for
execution. For example:
EXEC CICS ENABLE PROGRAM('EP9')
TALENGTH(750) GALENGTH(200) SHUTDOWN
EXEC CICS ENABLE PROGRAM('EP9')
START
The first command loads the task-related user exit program EP9, and causes a
200-byte work area to be obtained and associated with it. The first command
also schedules the allocation of a further 750-byte work area for each task that
subsequently invokes EP9, and the invocation of EP9 at CICS termination. The
second command starts the exit program, that is, it makes its entry point
capable of being invoked.
Note: If a task-related user exit program is enabled before it has been installed,
CICS scans the LPA for the program and may issue message
DFHLD0107I, meaning that it was unable to find the program in the LPA
and is using the DFHRPL version.
Enabling for specific invocation-types
Use the following options of the EXEC CICS ENABLE command to cause your exit
program to be invoked at specific events:
INDOUBTWAIT
specifies that, at phase 2 syncpoint time, if CICS is in-doubt about the
outcome of the UOW, the exit program is to be invoked with the UERTWAIT
verb (wait), instead of a forced definition of UERTCOMM (commit) or
UERTBACK (backout). UERTWAIT signifies that CICS does not yet know
the outcome of the UOW. In response to a UERTWAIT call, the task-related
the task-related user exit program
280