parameter list in your test program, upon which operations can be performed.
Running your program on a terminal before you use it properly means that you can
use the EDF transaction to help debug your program. You can also make the
program interactive, sending and receiving data from the terminal.
If you find that CICS does not offer any autoinstall models to your program, you can
create a test autoinstall program that forces the model name (AUTINSTNAME) you
want. With a VTAM buffer trace running, try to log the device on to CICS. If CICS
does not attempt to send a BIND, check the following:
v Does the model TERMINAL refer to the correct TYPETERM? (Or alternatively, is
the TYPETERM in question referred to by the correct TERMINAL definition?)
v Is the TERMINAL definition AUTINSTMODEL(YES or ONLY)?
v Have you installed the group containing the autoinstall models (TERMINAL and
TYPETERM definitions)?
If CICS attempts to BIND, compare the device’s CINIT RU to the CICS BIND, and
make corrections accordingly.
It is very important that you ensure that the VTAM LOGMODE table entries for your
terminals are correct, rather than defining new autoinstall models to fit incorrectly
coded entries. Bear in mind, while you are testing, that CICS autoinstall does not
work if a LOGMODE entry is incorrectly coded.
Note that you cannot force device attributes by specifying them in the TYPETERM
definition. For autoinstall, the attributes defined in the LOGMODE entry must match
those defined in the model; otherwise the model will not be selected. You cannot
define a terminal in one way to VTAM and in another way to CICS.
If your control program abends, CICS does not, by default, cause a transaction
dump to be written. To cause a dump to be taken after an abend, your program
must issue an EXEC CICS HANDLE ABEND command.
The sample programs and copy books
The CICS-supplied default autoinstall program is an assembler-language
command-level program, named DFHZATDX. The source of the default program is
provided in COBOL, PL/I, and C, as well as in assembler language. The names of
the supplied programs and their associated copy books, and the CICSTS13.CICS
libraries in which they can be found, are summarized in Table 25. Note that the
COBOL, PL/I, and C copy books each have an alias of DFHTCUDS.
Table 25. Autoinstall programs and copy books
Language Member name Alias Library
Programs:
Assembler
COBOL
PL/I
C/370
DFHZATDX
DFHZCTDX
DFHZPTDX
DFHZDTDX
None
None
None
None
SDFHSAMP
SDFHSAMP
SDFHSAMP
SDFHSAMP
naming and testing the control program