IBM x Series 200 Computer Drive User Manual


 
2 Hardware Maintenance Manual: xSeries 200
YES. Schedule maintenance with the customer. Shut down all systems related to the
cluster. Run storage test.
NO. Go to step 2.
2. IF THE SYSTEM IS NOT PART OF A CLUSTER:
Power-off the computer and all external devices.
Check all cables and power cords.
Set all display controls to the middle position.
Power-on all external devices.
Power-on the computer.
Record any POST error messages displayed on the screen. If an error is
displayed, look up the first error in the POST error codes on page 94.
Check the System Error Log. If an error was recorded by the system, see
Chapter . Symptom-to-FRU index, on page 85.
Start the Diagnostic Programs. See Diagnostic programs and error
messages on page 10.
Check for the following responses:
a. One beep.
b. Readable instructions or the Main Menu.
3. DID YOU RECEIVE BOTH OF THE CORRECT RESPONSES?
NO. Find the failure symptom in Chapter . Symptom-to-FRU index, on page 85.
YES. Run the Diagnostic Programs. If necessary, refer to Diagnostic programs and
error messages on page 10.
If you receive an error, go to Chapter . Symptom-to-FRU index, on page 85.
If the diagnostics completed successfully and you still suspect a problem, see
Undetermined problems on page 100.