IBM x Series 200 Computer Drive User Manual


 
96 Hardware Maintenance Manual: xSeries 200
187
(VPD serial number not set.)
1. Set serial number in Setup
2. System Board
188
(Bad EEPROM CRC #2)
1. Run Configuration/Setup
2. System Board
189
(Three attempts were made to
access the server with invalid
passwords)
1. Run Configuration/Setup, enter the administrator password
2. System Board.
201
(Memory test error, see
"Memory Settings" on page
31.) If the server does not
have the latest level of BIOS
installed, update the BIOS to
the latest level and run the
diagnostic program again.
1. Run memory diagnostics.
2. DIMM
3. System Board
229
(Cache error)
1. Microprocessor
289
(DIMM has been disabled by
user or system, see "Memory
Settings" on page 31.)
1. Run Configuration/Setup, if disabled by user
2. Disabled DIMM, if not disabled by user.
301
(Keyboard or keyboard
controller error)
1. Keyboard
2. System Board
303
(Keyboard controller error)
1. System Board
2. Keyboard
602
(Invalid diskette boot record)
1. Diskette
2. Diskette Drive
3. Cable
4. System Board
604
(Diskette drive error)
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
662
(Diskette drive configuration
error)
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
Error Code/Symptom FRU/Action