Symptom-to-FRU index 91
201-XXX-999
(Multiple DIMM failure, see
error text.)
1. See error text for failing DIMMs
202-XXX-001
(Failed System Cache test)
1. Microprocessor CPU 1
206-XXX-000
(Failed Diskette Drive test)
1. Cable
2. Diskette Drive
3. System Board
215-XXX-000
(Failed IDE CD-ROM test)
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
217-XXX-000
(Failed BIOS Fixed Disk test)
Note: If RAID is
configured, the fixed
disk number refers to
the RAID logical
array.
1. Fixed Disk 1
217-XXX-001
(Failed BIOS Fixed Disk test)
Note: If RAID is
configured, the fixed
disk number refers to
the RAID logical
array.
1. Fixed Disk 2
217-XXX-002
(Failed BIOS Fixed Disk test)
Note: If RAID is
configured, the fixed
disk number refers to
the RAID logical
array.
1. Fixed Disk 3
264-XXX-0NN
(NN = SCSI ID of failing Tape
Drive)
1. Tape Cartridge, if user executed the Read/Write Tape Drive test (XXX = 256)
2. SCSI or power cable connected to the tape drive with SCSI ID NN
3. Tape drive with SCSI ID NN – refer to Help and Service Information appendix of
tape drive’s User Guide.
4. I/O Legacy Board or SCSI Controller – run SCSI Controller diagnostic to
determine of SCSI bus is functioning properly.
264-XXX-999
(Errors on multiple tape
drives, see error text for more
info)
1. See error messages/text in the PC Doctor error log for detailed information on
each individual tape drive error.
Error Code/Symptom FRU/Action