90 Hardware Maintenance Manual: xSeries 200
015-XXX-198
(USB device connected
during USB test)
1. Remove USB devices from USB1 and USB2
2. Re-run test
3. System Board
020-XXX-000
(Failed PCI Interface test)
1. System Board
030-XXX-000
(Failed Internal SCSI interface
test)
1. System Board
030-XXX-00N
(Failed SCSI test on PCI slot
N. Check system error log
before replacing a FRU.)
1. Adapter in Slot N
035-XXX-099 1. No adapters were found.
2. If adapter is installed re-check connection.
035-XXX-S99
(Failed RAID test on PCI slot
S. S = number of failing PCI
slot. Check System Error Log
before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-SNN
(Check System Error Log
before replacing a FRU. S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99
(RAID adapter initialization
failure)
1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2. Cable
3. Adapter
075-XXX-000
(Failed Power Supply test)
1. Power Supply
089-XXX-001
(Failed Microprocessor test)
1. Microprocessor
180-XXX-003
(Failed System Board LED
test)
1. System Board
201-XXX-0NN
(Failed Memory test, see
"Memory Settings" on page
31.) NN = DIMM location.
1. DIMM Location J1-J4
2. Memory card