IBM x Series 200 Computer Drive User Manual


 
4 Hardware Maintenance Manual: xSeries 200
Server features
The design of the 200 takes advantage of advancements in data storage and memory
management. The server combines:
Impressive performance using an innovative approach to microprocessor
utilization
The server comes with one Celeron
®
or Pentium
®
III microprocessor installed.
Table 1. Features and Specifications.
Microprocessor: Supports one
microprocessor (depending on your
model)
Intel
®
Pentium
®
III with 256 KB
Level-2 cache and MMX
(MMX2) technology
or
Intel
®
Celeron
®
with 128 KB
Level-2 cache and MMX
(MMX2) technology
Memory:
Minimum: 64 MB
Maximum: 1.5 GB
Type: PC133 MHz, ECC SDRAM,
unregistered DIMMs only
Slots: 3 dual inline
Drives: (depending on your model)
Diskette: 1.44 MB
CD-ROM: IDE
Hard disk drive
Tape drive
Expansion bays:
Two 5.25-in. bays (one CD-ROM
drive installed)
Two 3.5-in. bays (one diskette
drive installed)
Three 3.5-in. slim-high bays
available
PCI expansion slots:
Three 33 MHz/32-bit on the
system board (some models come
with a SCSI adapter installed)
Two 33 MHz/32-bit on the PCI
Bus extender board
AGP slot: Accelerated graphics port
(AGP)
Power supply:
One 330 watt (90-240 V ac)
Video:
S3 Savage 4 AGP video adapter
Compatible with SVGA and
VGA
8 MB SDRAM video memory
Size:
Height: 470 mm (18.5 in.)
Depth: 508 mm (19.9 in.)
Width: 165 mm (6.5 in.)
Weight: approximately 19.5 Kg
(43 lb.) when fully configured or
15.9 Kg (35 lb.) minimum
Integrated functions:
10BASE-T/100BASE-TX
Ethernet controller on the
system board
Two serial ports
One parallel port
Two USB ports
Keyboard port
Mouse port
MIDI port
Audio ports
Line out
Line in
Mic
Dual-channel bus mastering
IDE controller
Acoustical noise emissions:
Sound power, idling: 6.6 bel
maximum
Sound power, operating: 6.8 bel
maximum
Environment:
Air temperature:
Server on: 10° to 35° C (50.0°
to 95.0° F). Altitude: 0 to 914
m (2998.7 ft.)
Server on: 10° to 32° C (50.0°
to 89.6° F). Altitude: 914 m
(2998.7 ft.) to 2133 m (6998.0
ft.)
Server off: 10° to 43° C (50.0°
to 109.4° F). Maximum
altitude: 2133 m (6998.0 ft.)
Humidity:
Server on: 8% to 80%
Server off: 8% to 80%
Heat output:
Approximate heat output in British
Thermal Units (Btu) per hour
Minimum configuration: 341 Btu
(100 watts)
Maximum configuration: 1604 Btu
(470 watts)
Electrical input:
Sine-wave input (50-60 Hz)
required
Input voltage low range:
Minimum: 90 V ac
Maximum: 137 V ac
Input voltage high range:
Minimum: 180 V ac
Maximum: 265 V ac
Input kilovolt-amperes (kVA)
approximately:
Minimum: 0.08 kVA