IBM x Series 200 Computer Drive User Manual


 
Symptom-to-FRU index 99
Processor board LEDs
01298101
(Bad update data for
microprocessor)
1. Ensure all microprocessors are the same stepping level and cache size.
2. Microprocessor
01298200
(Microprocessor speed
mismatch)
1. Ensure all microprocessors are the same speed.
I9990301
(Fixed boot sector error)
1. Hard Disk Drive
2. If RAID system, refer to the Hardware Maintenance Manual for the specific RAID
adapter.
3. SCSI Backplane
4. Cable
5. System Board
I9990305
(Fixed boot sector error, no
operating system installed)
1. Install operating system to hard disk drive.
I9990650
(AC power has been restored)
1. Check cable
2. Check for interruption of power supply
3. Power Cable
Other numbers Follow instructions on screen.
Table 16. .
LED Cause
Fan 1. Replace the fan assembly.
Memory 1. Replace the DIMM indicated by the lit DIMM error.
CPU 1. If a microprocessor LED is on for a microprocessor connector that has
a terminator card installed instead of a microprocessor, the
microprocessors are not installed in the correct order. See Removing
and installing a microprocessor on page 54 for information about the
correct order for installing microprocessors and VRMs.
2. Turn off the server, reseat the microprocessor, and restart the server.
3. Replace the microprocessor.
VRM 1. Turn off the server, reseat the VRM indicated by the lit VRM error
LED, and restart the server.
2. Replace the VRM
Error Code/Symptom FRU/Action