IBM x Series 200 Computer Drive User Manual


 
22 Hardware Maintenance Manual: xSeries 200
Message Description
Couldnt allocate resources. Explanation: An unknown error has occurred when trying to
allocate needed resources for the AFT Module.
Action:
Check the server configuration. If the problem persists,
contact your network supplier.
Verify that the Ethernet controller is enabled. If the
Ethernet controller is enabled, run the diagnostic
programs.
AFT group for primary
adapter in slot nnn already
exists.
Explanation: An attempt was made to rebind an adapter
already in an AFT group.
Action: Check the AFT slot numbers for existing AFT teams.
If the problem persists, contact your network supplier.
Error locating device control
table (DCT) addresses in
internal table. Make sure that
you have loaded LAN
drivers after loading
AFT.NLM.
Explanation: The bind command was entered prior to
loading the device driver. The device driver must be loaded
after loading AFT.NLM, but before any bind command can be
issued.
Action: Load the driver for the supported adapter and try
loading the AFT module again. If the problem persists,
contact your network supplier.
Insufficient number of
arguments specified.
Explanation: The appropriate or expected number of
parameters was not entered in a command.
Action: Check the parameters required for the given
command. If the problem persists, contact your network
supplier.
Duplicate slot numbers
detected.
Explanation: An attempt has been made to bind the same slot
number more than once.
Action: Check the slot numbers entered during the bind.
Adapter slot numbers must be valid and unique. If the
problem persists, contact your network supplier.
xxx is not supported for
AFT team.
Explanation: A bind command has been issued for adapters
not supported by AFT.NLM.
Action: Make sure that you attempt to bind only adapters
supported by AFT.NLM.
Primary and Secondary
adapters do not match. AFT
group is not created.
Explanation: A bind command was entered for an adapter
team that is a combination of server and client adapters. An
AFT team must be a grouping of the same classification of
adapter.
Action: Verify that all the adapters bound in a team are of the
same classification.
Requested number of
Secondary cards are not
found.
Explanation: The number of adapters specified in the bind
command could not be located.
Action: Verify the numbers and slot locations of the adapters
to be bound. If the problem persists, contact your network
supplier.
Failed to create AFT group.
Make sure that the drivers
for supported adapters are
loaded, primary adapter is
bound to protocols, and
secondary adapter is not
bound to any protocols.
Explanation: Binding of protocol failed. Protocol is either not
bound to any adapter or is bound to more than one adapter in
the group.
Action: Ensure that the protocol is bound to only adapter in
an AFT team.
Table 4. NetWare driver messages for the Ethernet controller.