IBM xSeries 330 Server User Manual


 
92 Hardware Maintenance Manual: xSeries 330
201 (Memory test error, see "Memory
Settings" on page 33.) If the server does
not have the latest level of BIOS installed,
update the BIOS to the latest level and run
the diagnostic program again.
1. DIMM
2. System Board
229 (Cache error) 1. Processor
2. Optional Processor (if installed)
262 (DRAM parity configuration
error)
1. Run configuration / setup
2. Battery
3. System Board
289 (DIMM has been disabled by the
user or system, see "Memory Settings" on
page 33.)
1. Run Configuration/Setup, if disabled by user
2. Disabled DIMM, if not disabled by user.
3. System Board.
301 (Keyboard or keyboard controller
error)
1. Keyboard
2. System Board
303 (Keyboard controller error) 1. System Board
602 (Invalid diskette boot record) 1. Diskette
2. Diskette Drive
3. Cable
4. System Board
604 (Diskette drive error) 1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
605 (Unlock failure) 1. Diskette Drive
2. Drive Cable
3. System Board
662 (Diskette drive configuration error) 1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
762 (Coprocessor configuration error) 1. Run configuration setup
2. Battery
3. Processor
962 (Parallel port error) 1. Disconnect external cable on parallel port.
2. Run Configuration/Setup
3. System Board
11XX (System board serial port 1 or 2
error)
1. Disconnect external cable on serial port.
2. Run Configuration/Setup
3. System Board
Error Code/Symptom FRU/Action