IBM xSeries 330 Server User Manual


 
88 Hardware Maintenance Manual: xSeries 330
035-253-S99 (RAID adapter
initialization failure)
1. ServeRAID Adapter in slot S is not configured properly. Obtain
the basic and extended configuration status and refer to the
ServeRAID Hardware Maintenance Manual for more information.
2. Cable
3. SCSI Backplane
4. Adapter
089-XXX-001 (Failed Microprocessor
test)
1. Microprocessor 1
2. System Board
089-XXX-002 (Failed
Optional Microprocessor test)
1. Microprocessor 2
2. System Board
165-XXX-000 (Failed Service Processor
test)
1. System Board
180-XXX-000 (Diagnostics LED failure) 1. Run Diagnostic LED test for the failing LED.
180-XXX-001 (Failed information LED
panel test)
1. Switch Card / Information LED Panel
180-XXX-003 (Failed System Board LED
test)
1. System Board
180-XXX-005 (Failed SCSI
Backplane LED test)
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
201-XXX-0NN (Failed Memory test,
see "Memory Settings" on page 33)
1. DIMM Location slots 1-4 where NN = DIMM location.
Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN
4=DIMM 4
2. System Board
201-XXX-999 (Multiple DIMM failure, see
error text)
1. See error text for failing DIMMs
2. System Board
202-XXX-001 (Failed System Cache
test)
1. Microprocessor 1
2. System Board
202-XXX-002 (Failed System Cache test) 1. Microprocessor 2
2. System Board
206-XXX-000 (Failed Diskette Drive
test)
1. Try test with another diskette
2. Cable
3. Diskette Drive
4. System Board
215-XXX-000 (Failed IDE CD-ROM
test)
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
217-XXX-000 (Failed Fixed Disk
test)
Note: If RAID is configured, the fixed
disk number refers to the RAID
logical array
1. Fixed Disk 1
2. System Board
Error Code/Symptom FRU/Action