IBM xSeries 330 Server User Manual


 
Chapter 5. Installing options 51
Complete the following steps to install a hot-swap drive in a hot-swap drive bay:
Attention:
To maintain proper system cooling, do not operate the server for more than two
minutes without either a drive or a filler panel installed for each bay.
When you handle electrostatic discharge sensitive devices (ESD), take precautions
to avoid damage from static electricity. For details on handling these devices,
refer to Handling electrostatic discharge-sensitive devices on page 110.
1. Remove the filler panel from one of the empty hot-swap bays by inserting your
finger into the depression at the left side of the filler panel and pulling it away
from the server.
2. Install the hard disk drive in the hot-swap bay:
a. Ensure the tray handle is open (that is, perpendicular to the drive).
b. Align the rails on the drive assembly with the guide rails in the drive bay.
c. Gently push the drive assembly into the bay until the drive connects to the
backplane.
d. Push the tray handle toward the closed position until it locks the drive in
place.
3. Check the hard disk drive status indicators to verify that the hard disk drives are
operating properly. See Server controls and indicators on page 6 for the
location of the status indicators.)
When a ServeRAID adapter is installed and:
The amber light is on continuously, the drive had failed.
The green light flashes slowly (one flash per second), the drive is being
rebuilt.
The green light flashes rapidly (three flashes per second), the controller is
identifying the drive.
Replacing a drive in a hot-swap bay
You do not have to turn off the server to remove or install the hot-swap drives.
1. Before you remove a hot-swap hard disk drive that is not defective, back up all
important data.
Slim filler
Filler panel
Hard disk drive
Drive tray
Drive tray handle
(in open position)