6.3 Clock Distribution
In order to meet timing and avoid clock overloading, it is recommended to use point-
to-point clock distribution as shown in Figure 27.
Clock skew between interfacing devices is very critical and must be met. The maximum
skew must be measured between any two components. If designing a motherboard,
the skew must be measured to the expansion card device and not to the PCI connector.
Ensure that clock skew between all devices does not exceed the values in Section 6.2.
Figure 26. PCI Address/Data Topology
Table 25. PCI Address/Data Routing Guidelines
Parameter Routing Guidelines
Signal Group PCI Address/Data
Topology Daisy Chain
Reference Plane Ground
Characteristic Trace Impedance 55 Ω ±10%
Nominal Trace Width 5 mils
Nominal Trace Separation 10 mils
Spacing to Other Groups 20 mils
Limit the number of VIAS to 10 per Signal 10
Intel
®
IXP46X
Product Line
Network Processor
B5196 -01
A
PCI Slot
BBB
PCI Slot PCI Slot PCI Slot