107
Timeout values
The switch module timeout values determine the timeout values for all external ports on the switch. Table 22
describes the switch module timeout parameters. R_A_TOV, R_T_TOV, or E_D_TOV values must be the
same for all switch modules in the fabric.
✏ NOTE
Timeout values can be changed only if the switch module operational state is offline.
Network properties
Use the Network Properties window shown in Figure 16 on page 107 to change IP and SNMP configuration
parameters. After making changes, click OK to put the new values into effect. To open the Network Properties
window, click Switch ” Network Properties.
✏ NOTE
The Read Community, Trap Community, and Write Community settings are like passwords;
therefore, they are write-only fields. The current settings are not displayed.
Figure 16. Network Properties window
Table 22. Timeout values
Parameter Description
R_A_TOV Resource Allocation Timeout. Represents the maximum time a frame can be delayed in the
fabric and still be delivered. The default is 10000 milliseconds.
R_T_TOV Receiver Transmitter Timeout. The amount of time that Sync can be lost between two ports
before Link Failure is detected. The default is 100 milliseconds.
E_D_TOV Error Detect Timeout. Represents the maximum round trip time that an operation between two
N_Ports requires. The default is 2000 milliseconds.