Intel SBCEFCSW Switch User Manual


 
24 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Table 2. Switch configuration defaults
Parameter Default
Admin State Online
Broadcast Enabled True
Inband Enable True
Domain ID 1
Domain ID Lock False
Symbolic Name Fibre Channel Switch Module
R_T_TOV 100
R_A_TOV 10000
E_D_TOV 2000
FS_TOV 5000
DS_TOV 5000
Principal Priority 254
System Description Fibre Channel Switch Module
Configuration Last Saved By Initial
Configuration Last Saved On Initial
Table 3. Port configuration defaults
Parameter External port (0,15) default Internal port (1-14) default
Admin State Online Online
Link Speed Auto 2 Gbps
Port Type GL F
TL_Port Mode TLTargetMode TLTargetMode
ISL Security Any Any
Symbolic Name Port0 or Port15 Port1 – Port14
ALFairness False False
ARB_FF False False
InteropCredit 0 0
ExtCredit 0 0
FanEnable True True
LCFEnable False False
MFSEnable True True
MFS_TOV 10 10
MSEnable True True