Intel SR1450 Computer Accessories User Manual


 
Hardware Installations and Upgrades
Intel
®
Server Chassis SR1450 User Guide 29
Removing the Processor Air Duct
1. Observe the safety and ESD precautions at the beginning of this book. See “Safety
Information.”
2. Power down the server and unplug all peripheral devices and the AC power cable(s).
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.”
4. Lift the processor air duct from its location over the two processor sockets.
TP01596
Fan
4A/4B
Fan
3A/3B
Fan
2A/2B
Fan
1A/1B
Figure 13. Removing the Processor Air Duct
Installing the Processor Air Duct
1. Observe the safety and ESD precautions at the beginning of this book. See “Safety
Information.”
2. Power down the server and unplug all peripheral devices and the AC power cable(s).
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.”
4. If you are installing the processor air duct for the first time after installing a second processor,
remove the tab on the back side of the processor air duct. See Figure 14.