Hardware Installations and Upgrades
36
13. Connect the floppy drive data cable that was included with your kit between the interposer
board and the server board. See letters “B” and “C” in the figure. See your server board
documentation for assistance in locating the connector location on the server board.
14. Connect the longest of the two device power cables coming from the backplane power
connector. See letter “D” in the figure.
TP01606
B
D
C
A
Figure 23. Installing the Slimline Floppy Drive into the Chassis
15. Install the chassis cover. For instructions, see “Installing the Chassis Cover.”
16. (Optional) Install the front bezel. For instructions, see “Removing and Installing the Front
Bezel.”
17. Plug all peripheral devices and the AC power cable(s) back into the server.
Removing a Floppy Drive from the Slimline Bay
1. Observe the safety and ESD precautions at the beginning of this book. See “Safety
Information.”
2. Power down the server and unplug all peripheral devices and the AC power cable(s).
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover.”
4. Remove the front bezel if it is installed. For instructions, see “Removing and Installing the
Front Bezel.”
5. Detach the power and data cables from the rear of the floppy drive.
6. Detach the data cable from the server board and remove the cable from the chassis.
7. Push in on the blue lever at the rear of the drive carrier.
8. Slide the floppy drive carrier out through the front of the chassis.
9. Remove the screw that attaches the interposer board to the drive. Lift the interposer board from
the drive.
10. Remove the flat flex cable from the floppy drive and from the interposer board.
11. Press downward on the right side of the carrier to release the drive from the drive carrier.
12. Store the floppy drive carrier, the interposer board, the flat flex cable, and the floppy drive data
cable for future use.
13. Install the slimline filler panel into slimline bay if no drive is to be installed into the bay.