JVC DLA-G150CLU Projector User Manual


 
DLA-G150CLU
DLA-G150CLE
1-34
No.51931
67
ENGLISHDEUTSHFRANÇAISITALIANOESPAÑOL
Warning Messages
The following shows the warning messages that can be displayed on the screen. When a warning message is displayed, take
the corrective action described here.
Message Cause Corrective action Page
No device is connected to the
input terminal.
The terminal is connected but no
signal is output from the
connected device.
* The selected input mode (input
terminal) name is shown in the
first line of the massage.
Connect a device to the selected
terminal.
Operate the connected device
and output a signal.
9, 11,
24 ~ 29,
33
The frequency of the input video
signal is out of range.
The selected input mode (input
terminal) name is shown in the
first line of the message.
Input the video signals whose
frequency is within the projector’s
specifications.
22, 23,
70
Though the frequency of the input
video signal is within the
acceptable range, other items
such as resolution are out of the
projector’s specifications.
The selected input mode (input
terminal) name is shown in the
first line of the message.
Input the video signals that
satisfies the projector’s
specifications.
22, 23,
70
When the FREEZE button is
pressed, this message appears
for a few seconds.
When a button not acceptable is
pressed during freezing, this
message appears for a few
seconds to notify that the image is
being frozen.
To release freezing, press the
FREEZE button on the remote
control.
12, 37
When the FREEZE button is
pressed for the video signals that
cannot be frozen (UXGA 60Hz,
SXGA 60Hz.), this message
appears for a few seconds to
notify that the image cannot be
frozen.
* To forcibly clear the message,
press the EXIT button.
Freeze function does not work for
the inputted video signals.
To use this function, input the
video signals that can be frozen.
12, 37
PC 1
No Input
PC 1
Frequency of input signal is out of range.
PC 1
Signal is not supported.
FREEZE
FREEZE
66
Warning Indication
If something abnormal has occurred with the projector, the warning status will be indicated by the combination of lighting the
indicators on the control panel as shown in the following table. Then, the projector automatically stops projection and runs the
cooling fan for about 120 seconds.
Warning indication table:
* For individual indicator lighting, refer to page 58.
Action to be taken for warning indication
Stopping the projector:
After the cooling fan has stopped, take the following action.
No. 1 : Check that the cover for replacing the light-source lamp and the front panel are securely attached, and then, press
the OPERATE button for one second or more to turn on the projector for retrying.
No. 2 : Check that the cover for replacing the light-source lamp and the front panel are securely attached, and then, press
the OPERATE button for one second or more to turn on the projector for retrying.
No. 3 : Press the OPERATE button for one second or more to turn on the projector for retrying.
Nos. 4-7 : Follow the next steps.
1. Turn off the MAIN POWER switch and unplug the power cord from the wall outlet.
2. Take an action according to the number.
No. 4 : Set the filter in place.Then, leave the projector until it cools down.
No. 5 : Check that nothing is blocking the air inlet nor outlet, and wait until the inside cools down.
No. 6 : Check that nothing is blocking the air inlet nor outlet, and wait until the inside cools down.
No. 7 : Leave the projector until it cools down.
3. Plug in the power cord again, turn on the MAIN POWER switch, and press the OPERATE button for one second or
more to turn on the projector for retrying.
Retrying operation:
Plug in the power cord again and operate the projector.
If the same warning indication is observed again, after the cooling fan has stopped, turn off the MAIN POWER switch, unplug
the power cord, and call your dealer for repair.
No.
Indicator
Warning content
LAMP TEMP STAND BY OPERATE
1 Blink Blink The light-source lamp does not light and projection
is not made.
2 Blink Blink The light-source lamp has suddenly gone off during
projecting an image.
3 Blink Blink Circuit operation is abnormal.
4 Blink Blink The filter is displaced.
5 Blink The internal temperature is too high. (Sensor 1)
6 Blink Blink The internal temperature is too high. (Sensor 2)
7 Blink Blink Blink Blink The cooling fan has stopped (locked).