Kodak 1200i Printer User Manual


 
KODAK 1200i WIDE-FORMAT PRINTING SYSTEM
Technical Training Guide 32
service).
C. After replacing a print head, it is a good practice to run the System Prime. This will
improve ink flow through the ink system and reduce print head errors.
NOTE: ensure printer is placed on a level
floor surface to avoid ink starvation (which
could cause ‘MAX INK TEMP EXCEEDED’
error messages) and related ink flow
problems. Check printer levelness by
placing a standard level on the platen
surface (remove media from platen).
Perform the following:
- A System Prime:
Select Utility Menu - Prime Menu - Serv. Station Menu - System Prime
- Print a Prime Test to check that all nozzles are properly firing
Select Utility Menu - Prime Menu - Prime Single - Prime
- Perform Print head alignments:
Bi-directional alignment:
Utility Menu / Calibration Menu / Color Db Menu /
Color Db Test
Geometric print heads alignment: Utility Menu / Calibration Menu / Color
Calib Menu / Vert. Calib Test / Horiz. Calib Test
Prime Test Color Dead Band Vertical Calibration
Horizontal Calibration