Kodak 1200i Printer User Manual


 
KODAK 1200i WIDE-FORMAT PRINTING SYSTEM
Technical Training Guide 36
2. Auto Clean Unit (Disposal) Bottle (prompted by ‘Empty Waste Bottle Now’
control panel/software suite message). Open Auto Clean Unit door, remove bottle
and dispose of ink in accordance with local guidelines).
3. Encoder Sensor. The carriage encoder sensor
will likely get dirty ~600 plot hours
and will need to be cleaned or image shifted output may be observed (see samples
below). Typically, random horizontal bands will first appear in the printed output,
followed by gradual image shift, then eventual data shift.
Cleaning Procedure:
- Remove power from printer.
- Manually move the carriage assembly to the
extreme left side of the printing surface.
- Place absorbent towels around base of carriage
assembly.
- Obtain Windex cleaning fluid and attach spray
tube (internal tube may need to be cut to allow for
inverted spray operation).
NOTE: Windex solution is strongly suggested for printers running the pigment ink
set as the ink can be difficult to clean from surfaces.