Kodak 1200i Printer User Manual


 
KODAK 1200i WIDE-FORMAT PRINTING SYSTEM
Technical Training Guide 48
system wide acceptable range is between 450 and 540 (go to Cartridge Status –
press outside keys to view individual cartridge status/information, refer to bottom
of page 8).
[<color>] Pen Error – Invalid OEM ID!
Translation: The pen OEM ID does not match the main-board OEM ID. For
ENCAD cartridge all OEM values should be 1. Replace cartridge under warranty
if one cartridge is different than the rest.
[<color>] Pen Error – Ink Warranty Mismatch!
Translation: The system was unable to update pen warranty status (ID-chip).
[<color>] Pen Error – Invalid Chip ID!
Translation: The pen ID chip serial number is invalid. Reseat or replace cartridge
under warranty.
For the above error messages replace the cartridge with a qualified
replacement. If cartridge replacement does not solve the issue then check
flex driver cable and trailing cable connectivity. Replace appropriate flex
driver cable. Replace trailing cable. Replace carriage board (defective jack
connector).
If the Pen Error is related to an ID-chip communication failure, the error message
format changes to the following:
[<color>] Pen Error – Code < # > (# ranges from 2 to 7)
Where:
2 = “<color> Pen Error - Pri CRC Failed!”
3 = “<color> Pen Error - Sec CRC Failed!”
4 = “<color> Pen Error - No Response!”
5 = “<color> Pen Error - Write Protected!”
6 = “<color> Pen Error - Copy Failed!”
7 = “<color> Pen Error - MAC Mismatch!”
Translation: The ID-chip or its connection is faulty.
These communication error messages are displayed in the “Cart Info” secondary
menu. This display menu is made visible by pressing the associated cartridge
color button (F1-F6).
604 K: BLACK QiD TSR: XXX
MFGl X-X-XXX OEM: 1 ID: 6
XXXXXXXXXXXXX
TSR FOUND +
NOTE: the TSR range is normally between 450 and 540; cartridges operate the
‘best’ between TSR levels between 480 and 510 however.