VI
1. Operating environment
1) Instrument should be operated only by qualied and trained personnel.
2) Handle the instrument with care, and do not apply strong shock to the instrument.
3) Avoid high temperature and humidity, direct sunlight, and dust when installing and storing the instrument.
Strictly observe the following environmental conditions.
Operating Transporting and storing
Environmental temperature 10 to 35 °C
─
15 to +55 °C
Relative humidity 30 to 90 % 10 to 95 %
4) Avoid condensation when using, transporting or storing the instrument.
5) Do not connect a digital camera other than that supplied with this instrument. Using other camera may
adversely affect the safety or performance of this instrument.
6) Install the instrument in a room where the lighting is 5 lux or less which you may barely manage to read a
newspaper.
2. Precautions on electric system
1) When the instrument has not been used for a long period of time, inspect the items below.
Inspect if the objective lens is free from soils.
Inspect if intensity of the lamps appropriately adjustable.
2) Install the system in a location where there is little risk of the plug being pulled out while operating. If the
plug should be pulled out accidentally, be sure to turn OFF the main power before plugging the system
back in.
3) Kowa is not liable for malfunctions and/or damages resulting from maintenance and/or repairs performed
by the third party other than an agent authorized by Kowa.
4) Kowa is not liable for malfunctions and/or damages resulting from maintenance and/or repairs using parts
other than repair parts specied by Kowa.
5) The input voltage should always be maintained within ± 10% of the rated voltage.
6) Do not turn on the ash lamp and adjust photography light intensity at the same time.
7) Wait for approx. 1 minute until the instrument has safely started up.
8) Do not turn the main power ON and OFF in succession. Allow an interval of at least 10 seconds before
turning the main power ON and OFF.
9) Be sure to turn OFF the main power before connecting an external device.
10) Do not touch the patient and connectors at the same time as it may adversely affect the safety.
11) Disinfect using alcohol the parts accessible by the patient.
12) The power supply must be provided for the sole use of this instrument.
3. Precautions when using this instrument
1) Carefully handle the objective lens as soiled or scratched part of the objective lens may be imaged as
white spots.
2) Always cover this instrument when not in use in order to protect them.
3) Do not apply strong shock or force to the objective lens.
4) Set a dial or knob with clicking positions to its designated position.
5) Do not press sharp instruments or tools against the LCD monitor or add excessive force to the monitor.
6) Never disassemble or adjust this instrument by yourself as it uses precision parts which requires special
tool for doing so.
4. Disposal precautions
When disposing this instrument, applicable federal, state, and local regulations must be observed. Ensure
that disposal is handled by a licensed industrial waste disposal contractor in accordance with the applicable
regulations and ordinances.
5. Replacement of the Aluminum Electrolytic Capacitor
The aluminum electrolytic capacitor for the ash lamp, which is used in the power supply section of this
instrument, is a component requiring regular replacements. The useful life of this type of components
may be signicantly reduced depending the frequency and conditions in which this instrument is used. If
the capacitor is used beyond its useful life, its electrolytic solution may leak or drain, which can result in
abnormal odor, smoke, bursting sound, and other failures.
The design life of the capacitor is 50,000 flashes when used in an ambient temperature of 25°C.
This is, however, only a guideline, and the capacitor may need to be replaced earlier depending on the
usage environment. In order to ensure safe and stable operation of this instrument, early replacement
of the aluminum electrolytic capacitor is recommended. Replacement of components requiring regular
replacement, such as aluminum electrolytic capacitor, is supported as a paid service. For more information
about replacement of such components, please contact Kowa or your Kowa dealer.
6. Prescription device caution:
Caution
Federal law restricts this device to sale by or on the order of a Physician or Practitioner.
For US market
Operating precautions