33
CHAPTER 2 SYSTEM CONFIGURATION
2
2.2 Using the Q64TCN with Redundant CPU
2.2 Using the Q64TCN with Redundant CPU
This section describes the use of the Q64TCN with the redundant CPU.
(1) GX Configurator-TC
GX Configurator-TC cannot be used when the redundant CPU accessed via an intelligent function module on an
extension base unit from GX Developer. Consider a communication path which does not go through the
intelligent function modules on the extension base unit.
Connect a personal computer with a redundant CPU using a communication path shown below.
Main base unit
Extension base unit
12
1
Direct connection to use the CPU
2
Connection through an intelligent function module on the main base unit
(Through Ethernet module, MELSECNET/H module, or CC-Link module)
(GX Configurator-TI cannot be used.)