Mitsubishi Electronics Q64TCTTN Network Card User Manual


 
63
CHAPTER 3 SPECIFICATIONS
3
3.4 Buffer Memory Assignment
3.4.1 Q64TCN buffer memory assignment list
60(3C
H
)
CH1
Loop
disconnection
detection dead
band
System area System area 0 R/W
Page 125,
Section
3.4.2 (34)
61(3D
H
)
CH1 Unused channel setting 0 R/W ×
Page 126,
Section
3.4.2 (35)
62(3E
H
)
CH1
E
2
PROM's PID constants read instruction
0R/W × ×
Page 127,
Section
3.4.2 (36)
63(3F
H
)
CH1
Automatic backup setting after auto tuning of PID
constants
0R/W × ×
Page 128,
Section
3.4.2 (37)
64(40
H
)
CH2
Input range
*9
2(TT)
7(RT)
*5
R/W ×
Page 96,
Section
3.4.2 (12)
65(41
H
)
CH2
Stop mode
setting
Stop mode
setting
Stop mode
setting
*7
1R/W ×
Page 103,
Section
3.4.2 (13)
66(42
H
)
CH2
Set value (SV)
setting
Set value (SV)
setting
Set value (SV)
setting
*7
0R/W
Page 104,
Section
3.4.2 (14)
67(43
H
)
CH2
Proportional
band (P) setting
Heating
proportional
band (Ph)
setting
Heating
proportional
band (Ph)
setting
*7
30 R/W ×
Page 105,
Section
3.4.2 (15)
68(44
H
)
CH2
Integral time (I)
setting
Integral time (I)
setting
Integral time (I)
setting
*7
240 R/W ×
Page 107,
Section
3.4.2 (16)
69(45
H
)
CH2
Derivative time
(D) setting
Derivative time
(D) setting
Derivative time
(D) setting
*7
60 R/W ×
Page 107,
Section
3.4.2 (17)
70(46
H
)
CH2 Alert set value 1
Alert set value
1
Alert set value
1
*7
0R/W
Page 108,
Section
3.4.2 (18)
71(47
H
)
CH2 Alert set value 2
Alert set value
2
Alert set value
2
*7
0R/W
72(48
H
)
CH2 Alert set value 3
Alert set value
3
Alert set value
3
*7
0R/W
73(49
H
)
CH2 Alert set value 4
Alert set value
4
Alert set value
4
*7
0R/W
74(4A
H
)
CH2
Upper limit
output limiter
Heating upper
limit output
limiter
Heating upper
limit output
limiter
*7
1000 R/W ×
Page 110,
Section
3.4.2 (19)
75(4B
H
)
CH2
Lower limit
output limiter
System area System area 0 R/W ×
76(4C
H
)
CH2
Output variation
limiter setting
Output
variation limiter
setting
Output
variation limiter
setting
*7
0R/W ×
Page 112,
Section
3.4.2 (20)
77(4D
H
)
CH2 Sensor correction value setting 0 R/W ×
Page 113,
Section
3.4.2 (21)
78(4E
H
)
CH2
Adjustment
sensitivity (dead
band) setting
Adjustment
sensitivity
(dead band)
setting
Adjustment
sensitivity
(dead band)
setting
*7
5R/W ×
Page 113,
Section
3.4.2 (22)
Address
(decimal
(hexadecimal))
Target
channel
or
current
sensor
(CT)
Setting contents
Default
value
*1
Read/
Write
*2
Automatic
setting
*3
E
2
PROM
write
availability
*4
Reference
Standard
control
Heating-
cooling
control
Mix control