Monarch 9820 Printer User Manual


 
Also, keep in mind the following:
The Printer Applicators are released for 110-volt sales only.
You can use thermal direct printing (no ribbon) or thermal transfer printing (with ribbon).
The Printer Applicators do not support continuous (non-indexed) supplies.
Printer Configuration Information
The default configuration packet settings are:
{
I
,A,0,0,0,0,0 p
B,3,1,1,0,0 p
C,0,0,0,0,0,0 p
D,1,0,2 p
E,{,,,", p ~,--,--,Od/Oa p
F,1,1,0,0,3 p
G,1,95,95 p }
The supply type must be center aperture (3).
Backfeed must be enabled (1). The dispense position
and backfeed distances must be set to 95 dots when
using 1/8-inch gap supplies.
Status Polling Information
ENQ Response Meaning
??
Powerup
A@
Online/Ready to receive data after label
has been applied
C@
Label is printing
CH
Label is printed
SB
Out of supplies
SD
Out of ribbon
E-4
Printer Differences