Orbit Manufacturing 2000 Printer User Manual


 
Page 8 - 3
MaintenanceOrbit™ 2000 Operation and Maintenance Manual
© GBC Films Group January 2001
MONTHLY
– Tighten and grease all roller chains
ANNUALLY
– Cleaning of the electrical assembly
ELECTRICAL
SHOCK
WARNING: Power must be disconnected to machine at fused disconnect!
– Dust can be removed by vacuuming the cabinet with a soft brush wand.
WARNING
WARNING: Never use compressed air to remove dust from the
inside of the electrical cabinet.
– Inspection of the electrical assembly.
– Tightness of terminals
– Circuit breaker wires
– Loose wires
– Protective Circuit inspection
– Check whether protective connectors are tight. Tighten loose connections. The safety of
protective circuits may be checked by feeding a current of at least 10 A (50 Hz) from the
PELV source for at least 10 seconds. The test is done between the PE terminal and
various points that are part of the protective circuit. See EN 60204-1, article 20.2.