– The voltage measured between the terminal PE and the test points may not exceed
U =3.3V for S= 1.o square millimeters
U = 2.6V for S= 1.5 sq. millimeters
U = 1.9V for S = 2.5 sq. millimeters
Where U is the largest drop in voltage and
S is the smallest effective diameter of the protective conductor in the
tested branch of the protective circuit.
– The number of measurements of the protective circuit link is given by the requirements
of particular regulations and standards valid in the user’s country.
– MAIN DRIVE AND FEED TABLE GEAR DRIVE
– Running in - 300 hrs -oil PP 90 H
– Normal operation - 400 hrs -oil PP 90 H
In case of higher demands the ecologically acceptable oil TOP-BLEND may be used. TOP-BLEND
allows for up to 10.000 operation hours between changes.
– VARIATOR
– Running in - 10.000 hrs - oil OTK 8 to 10
– Normal operation - 10.000 hrs - oil OTK 8 to 10