2-25
Features
Table 2-5. Power LED Indicators
LED Status Description Response
DC-Power Off
Green
Power is off
Power is on
None required - normal
None required - normal
Alarm Off
Amber
No alarm
Power failure
Abnormal Power temperature
Power FAN alarm
DC-Power alarm
None required - normal
Replace Power supply
Clean air passages
Replace Power supply
Replace Power supply
Figure 2-9. Power Supply Module Features
B
E
C
D
F
G
A
A Power cage
B Main power switch
C LED: DC ON (Green)
D LED: Alarm (Amber)
E Power supply modules
F Basic power slots
G Redundant power slot
Hot Swap FAN
The system has five hot swappable fan modules (six
fans). The failed fan module can be easily removed or
replaced without turning power off. Each fan module
has a fan alarm LED and each fan is redundant in
configuration. If one fan fails, its associated fan
changes its rotating speed to high. Table 2-6 lists the
fan redundant pairs. Figure 2-10 shows the fan
features from the front of the chassis and Figure 2-11
shows the fan features from the rear of the chassis.