Paradyne 3160-A3 Network Card User Manual


 
E. SNMP MIB Objects
E-26
February 2001 3160-A2-GB21-90
Where these object identifiers are defined as follows:
testLoopDTLB OBJECT IDENTIFIER ::= [wellKnownTests 2]
testMonQRSS OBJECT IDENTIFIER ::= [wellKnownTests 3]
testMon511 OBJECT IDENTIFIER ::= [wellKnownTests 4]
testSendQRSS OBJECT IDENTIFIER ::= [wellKnownTests 5]
testSend511 OBJECT IDENTIFIER ::= [wellKnownTests 6]
testSendV54Up OBJECT IDENTIFIER ::= [wellKnownTests 7]
testSendV54Down OBJECT IDENTIFIER ::= [wellKnownTests 8]
testSendFT1Up OBJECT IDENTIFIER ::= [wellKnownTests 9]
testSendFT1Down OBJECT IDENTIFIER ::= [wellKnownTests 10]
Generic Interface Test Table ifExtnsTestResult Object
(ifExtnsTestEntry 5)
This object contains the result of the most recently requested test. Only the
following values are supported by the DSU/CSU.
none(1) No test currently active.
inProgress(3) A test is currently in progress.
notSupported(4) The requested test is not supported.
unAbleToRun(5) The requested test cannot run due to the state of the unit.
Generic Interface Test Table ifExtnsTestCode Object
(ifExtnsTestEntry 6)
This object contains a code that contains more specific information on the test
result. This object is defined as an object identifier. Only the following values are
supported by the DSU/CSU.
none No further information is available. Used for the send pattern/code and
loopback tests.
inSyncNoBitErrors A monitor pattern (QRSS or 511) test has synchronized
on the pattern and has not detected any bit errors.
inSyncWithBitErrors A monitor pattern (QRSS or 511) test has synchronized
on the pattern and has detected bit errors.
notInSync A monitor pattern (QRSS or 511) test has not synchronized on
the requested pattern.