Paradyne 3160-A3 Network Card User Manual


 
3. Operation
3-8
February 2001 3160-A2-GB21-90
Table 3-4. Data Port LEDs
Name Color Meaning
DTR
Green Monitors the state of interchange circuit CD (CCITT 108/1, /2)
Data Terminal Ready received from the synchronous data DTE.
ON:
DTR is being asserted by the synchronous data DTE.
OFF:
DTR is not being asserted.
TXD
Yellow Monitors activity on interchange circuit BA (CCITT 103)
Transmitted Data. This is the data sent from the synchronous
data DTE to the data port on the DSU/CSU.
ON:
Ones are being received from the synchronous data DTE.
OFF:
Zeros are being received from the synchronous data DTE.
CYCLING:
Both ones and zeros are being received from the
synchronous data DTE.
RXD
Yellow Monitors activity on interchange circuit BB (CCITT 104)
Received Data. This is data sent to the synchronous data DTE
from the data port on the DSU/CSU.
ON:
Ones are being sent to the synchronous data DTE.
OFF:
Zeros are being sent to the synchronous data DTE.
CYCLING:
Both ones and zeros are being sent to the
synchronous data DTE.
CTS
Yellow Monitors the state of interchange circuit CB (CCITT 106)
Clear-to-Send sent to the synchronous data DTE.
ON:
CTS is being asserted by the DSU/CSU.
OFF:
CTS is not being asserted.
RTS
Yellow Monitors the state of interchange circuit CA (CCITT 105)
Request-to-Send received from the synchronous data DTE.
ON:
RTS is being asserted by the synchronous data DTE.
OFF:
RTS is not being asserted.