Paradyne 3160-A3 Network Card User Manual


 
H. Asynchronous Terminal Operation
H-20
February 2001 3160-A2-GB21-90
General Options Front Panel Equivalent Value (
Default in
Bold)
Generate Yellow Alarm
Signals
Gen Yellow
Enable
, Disable
Initial Self Test Self-Test
Enable
, Disable
Primary Clock Source Clock Src
Network
, DTE, Internal,
External, Port 1
External Clock Rate (KHz) Clock Rate 2048,
1544
, 8
Test Timeout Tst Timeout
Enable
, Disable
Test Duration Tst Duration 1120 (Default =
10
)
User Interface Front
Panel Options Front Panel Equivalent Value (
Default in
Bold)
Front Panel Access FP Access
Enable
, Disable
Front Panel Pass-Through FP Pass Enable,
Disable
User Interface:
Communication Port
Options Front Panel Equivalent Value (
Default in
Bold)
Port Use Com Use Mgmt, ASCII, Daisy,
Terminal
Port Type Com Type
Asynchronous
,
Synchronous
Clock Source Com Clk
Internal
, External
Data Rate Com Rate 1.2, 2.4, 4.8,
9.6
, 14.4, 19.2,
38.4
Character Length Char Length 7,
8
Parity CParity
None
, Even, Odd
Stop Bits CStop Bits
1
, 1.5, 2
Ignore Control Leads Ignore DTR
Disable
, DTR
Password Required Password Enable,
Disable
Inactivity Timeout CmInActTm Enable,
Disable
Disconnect Time CmDiscTm 160 (Default =
5
)