5-6 MonarchNet2 Operating Instructions
SET PRN RELay FILter [OFF/NONE/RFID/NONRFID]
Sets the Smart Relay Filter to
OFF Does not forward any data - primary printer prints all
batches.
NONE Forwards ALL data to primary AND partner printer – batches
print on both the primary and partner printers.
RFID Forwards RFID batches to the partner printer.
NON-RFID Forwards non-RFID batches to the partner printer.
The default is None.
Setting the Smart Relay Filter to None causes the batch to print on BOTH
the primary and partner printers. To use this option, you may need a
custom script (application) to perform additional filtering. For example, a
custom application filters which format is printed between two printers
loaded with different-sized supplies: 4x2 and 4x6. Our Professional
Services group can develop custom RFID scripts (applications) or other
types of data manipulation scripts. Call Customer Service for more
information.
SET PRN RELay COUNTer [NONE|0-9999]
Sets the Smart Relay Counter Number to None (no counter is used) or 0 to
9999 (beginning value for counter). The default is None.
SET PRN RELay POS [0-2400] [0-2400]
Sets the Smart Relay Field position (collation field) in graphic dot row and
column values. The default is 0,0.
The CLear and SHow commands can also be used on these commands.
Using CLear sets the values back to their defaults.
Example SET PRN REL POR S2
Sets the Smart Relay port to serial port 2 (enables the Smart Relay
system).
Note: After sending this command, turn off the printer. Wait several
seconds and then turn on the printer for the command to take
effect.
Example SET PRN REL FIL NONRFID
Sets the Smart Relay filter to non-RFID, so batches with no RFID Data Field
are sent to the partner printer.