Promise Technology M310p Computer Hardware User Manual


 
Chapter 4: Management with WebPAM PROe
77
5. Click the Submit button.
6. In the warning box, click the OK button.
7. In the confirmation box, type the word confirm in the field provided.
8. Click the OK button.
When the controller shuts down, your WebPAM PROe connection will be
lost.
9. Wait for two to three minutes.
10. In your browser, log into WebPAM PROe once again.
If you cannot log in, wait for 30 seconds, and try again. Repeat until login is
successful.
Monitor the Restart
To monitor a restart, you must use the Command Line Interface (CLI) though a
serial connection to the VTrak.
At the “administrator@CLI>” prompt, type shutdown -a restart.
When the “Login:” prompt appears, the restart is finished.
Controllers
The Controllers–Information tab provides information about the controllers in a
VTrak subsystem. Controller information includes:
Controller ID (1 or 2)
Alias, if assigned
Status – OK means normal
Vendor
Model
Revision Number
WWN – World Wide Name of the controller
To identify the VTrak subsystem housing this controller:
1. Click the Subsystem icon in Tree View.
2. Click the Controllers icon.
3. Click on the Locate Controller button.
The Controller Status LED and Dirty Cache LED on the back of the
Controller, will flash for one minute. See the illustration below.