Q-Logic 16HA Switch User Manual


 
Preliminary
Power Supply
SANbox-16HA Fibre Channel Switch
4-6 Removal/Replacement Procedures 59005-03 Rev. A Installer’s/User’s Manual
Power Supply
Removal
If the Switch contains two Power Supplies, either supply is “Hot-Pluggable”. That
is, one supply can be removed while the Switch is powered-up and operating as
long as the other supply is operating properly.
1. Refer to Figure 4-6. Use a large flat-blade screwdriver to turn each of the two
Locking-Screws 1/4 turn counterclockwise.
2. Pull the Power Supply straight out of the back of the Switch Chassis. If the
Switch contained two power supplies and will now be operating with only
one until the second supply is replaced, install the Cover Plate over the bay. A
Cover Plate came with the Switch.
Figure 4-6 Power Supply Removal
DANGER:
Do not attempt to open the covers of the power supply. Power supplies are not
serviceable and must be replaced as a unit.
GEFAHR:
Versuchen Sie auf keinen Fall, die Abdeckung des Netzteils zu entfernen. Die Netzteile
sind nicht wartbar. Sie müssen als ganze Einheit ersetzt werden.
DANGER:
L’alimentation électrique ne se répare pas. En cas de panne, la remplacer au complet.
Ne pas essayer d’en ouvrir le boîtier.
Fan
Locking Screws
Power Supply
Chassis Back