4 – Managing Switches
Configuring a Switch
59226-00 B 4-23
A
4.7.3.1
Timeout Values
The switch timeout values determine the timeout values for all ports on the switch.
Table 4-5 describes the switch timeout parameters. The timeout values must be
the same for all switches in the fabric.
NOTE: Mismatched timeout values will disrupt the fabric. These should not be
changed unless absolutely necessary. Therefore, the switch must be
offline to change these values. Use the Switch Properties dialog to take
the switch offline.
Table 4-5. Timeout Values
Parameter Description
R_A_TOV Resource Allocation Timeout: Represents the maximum time a frame
could be delayed in the Fabric and still be delivered. The default is
10000 milliseconds.
E_D_TOV Error Detect Timeout: Represents the maximum round trip time that
an operation between two N_Ports could require. The default is 2000
milliseconds.