A – Command Line Interface
Set Config Command
59226-00 B A-45
A
threshold
Initiates a configuration session by which to generate and log alarms for selected
events. The system displays each event, its triggers, and sampling window one
line at a time and prompts you for a value. For each parameter, enter a new value
or press the Enter key to accept the current value shown in brackets. These
parameters must be saved in a configuration and activated before they will take
effect. Refer to the “Config Command” on page A-11 for information about saving
and activating a configuration. Table A-11 describes the Set Config Threshold
parameters. The switch will down a port if an alarm condition is not cleared within
three consecutive sampling windows (by default 30 seconds). Reset the port to
bring it back online. An alarm is cleared when the threshold monitoring detects
that the error rate has fallen below the falling trigger.
Table A-11. Set Config Threshold Parameters
Parameter Description
Threshold Monitoring Enabled Master enable/disable parameter for all events.
Enables (True) or disables (False) the generation
of all enabled event alarms. The default is False.
CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled
The event type enable/disable parameter.
Enables (True) or disables (False) the generation
of alarms for each of the following events:
CRC errors
Decode errors
ISL connection count
Device login errors
Device logout errors
Loss-of-signal errors
Rising Trigger The event count above which a rising trigger
alarm is logged. The switch will not generate
another rising trigger alarm for that event until the
count descends below the falling trigger and again
exceeds the rising trigger.
Falling Trigger The event count below which a falling trigger
alarm is logged. The switch will not generate
another falling trigger alarm for that event until the
count exceeds the rising trigger and descends
again below the falling trigger.
Sample Window The period of time in seconds in which to count
events.