Q-Logic 59226-00 B Switch User Manual


 
A – Command Line Interface
Set Log Command
59226-00 B A-53
A
None
Specifies no severity levels for display on the screen.
level [filter]
Specifies the severity level given by [filter] to use in monitoring and logging events
for the specified components or ports. [filter] can be one of the following values:
Critical
Monitors critical events. The critical level describes events that are generally
disruptive to the administration or operation of the fabric, but require no
action.
Warn
Monitors warning and critical events. The warning level describes events
that are generally not disruptive to the administration or operation of the
fabric, but are more important than the informative level events.
Info
Monitors informative, warning, and critical events. The informative level
describes routine events associated with a normal fabric. This is the default
severity level.
None
Monitors none of the severity levels.
port [port_list]
Specifies one or more ports to monitor for events. Choose one of the following
values:
[port_list]
Specifies port or ports to monitor. Use a <space> to delimit values in the list.
Ports are numbered beginning with 0.
All
Specifies all ports.
None
Disables monitoring on all ports.
restore