Renesas M3062PT3-RPD-E Network Card User Manual


 
M3062PT3-RPD-E User’s Manual 2. Setup
REJ10J0040-0600 Rev.6.00 July 01, 2006 Page 31 of 104
2.8.1 Connecting to a 80-pin 0.65mm Pitch Foot Pattern
Figure 2.9 shows how to connect 80-pin 0.65mm pitch foot pattern on the user system to the M3062PT-80FPB (not included),
and here following is its procedure.
For details on the M3062PT-80FPB (not included), refer to its user's manual.
(1) Attach the NQPACK080SB included with the M3062PT-80FPB to the user system.
(2) Attach the YQPACK080SB included with the M3062PT-80FPB to the NQPACK080SB and secure it with the
YQ-GUIDE's.
(3) Attach the CN2 side of the M3062PT-80FPB to the CN2 side of the package converter board connected to the emulation
pod probe.
(4) Attach the M3062PT-80FPB to the YQPACK080SB.
*
CN2 side
(3)
(1)
80-pin 0.65mm pitch
(PRQP0080JA-A) foot pattern
No. 1 pin
User system
M3062PT- 80FPB (not included)
FLASH MCU, etc.
On-board evaluation
*: These four items are included in one package.
YQPACK080SB
NQPACK080SB
HQPACK080SB
(2)
(4)
YQ-GUIDE (x 4)
These corners are not round.
Package converter board
Tip of emulation
pod probe
(not included)
Figure 2.9 Connecting to a 80-pin 0.65mm pitch foot pattern
CAUTION
Note on Connecting the User System:
z Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation
pod.
IMPORTANT
Note on Connectors of the Converter board:
z The small connectors of the M3062PT-80FPB are guaranteed for only 50 insertion/removal iterations.