3.7 Trace Window
The trace window is used to show the results of real-time trace measurements.
(1) Trace window
1) Opening the trace window
Trace window
Clicking this button opens the trace window.
2) Trace window
Trace window
The trace window is used to show the results of real-time trace
measurements. It has the following four display modes. Mixed
mode also can be displayed.
- Bus mode
Bus information per cycle can be inspected. The contents are
displayed in order of execution paths.
- Disassemble mode
The execution paths of the executed instructions can be
inspected. The contents are displayed in order of execution
paths.
- Source mode
The execution paths of the source program can be inspected.
- Data access mode
Data read/write cycles can be inspected.
The trace window shows the measurement result when a
real-time trace measurement has finished. The trace window
remains blank until the real-time trace measurement in progress
finishes.