2.8.3 Connecting to a 100-pin 0.65mm Pitch Foot Pattern (Part 1)
Figure 2.11 shows how to connect a 100-pin 0.65mm pitch foot pattern on the user system to the M3T-F160-100NRB (not
included), and here following is its procedure. For details on the M3T-F160-100NRB (not included), refer to its user's manual.
(1) Attach the NQPACK100RB included with the M3T-F160-100NRB to the user system.
(2) Attach the YQPACK100RB included with the M3T-F160-100NRB to the NQPACK100RB and secure it with the
YQ-GUIDE's.
(3) Attach the CN2 side of the M3T-F160-100NRB to the CN2 side of the package converter board connected to the emulation
pod probe.
(4) Attach the M3T-F160-100NRB to the YQPACK100RB.
Figure 2.11 Connecting to a 100-pin 0.65mm pitch foot pattern (1/3)
CAUTION
Note on Connecting the User System:
z Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator or
user system.
IMPORTANT
Note on Connectors of the Converter board:
z The connectors of the M3T-F160-100NRB are guaranteed for only 50 insertion/removal iterations.
*
CN2 side
(3)
(1)
100-pin 0.65mmpitch
(PRQP0100JB-A) foot pattern
NO. 1 pin
User system
M3T-F160-100NRB
(not included))
FLASH MCU, etc.
On-board evaluation
: These four items are available in one package.
YQPACK100RB
NQPACK100RB
HQPACK100RB168
(not included)
(2)
(4)
YQ-GUIDE (x4)
These corners are not round.
Package converter board